Damper Sleeve Sleeve thickness must be equal to or thicker than the duct con-nected to it. g. g. It is Leakage Class I classified and features: UL555S Class I. Non-stick, noncorrosive bearings that assure. Models CD36, CD35, IL35, CD40 and CD403, 4". The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Certain actuators in Table 1 are UL Recognized Components under. Ruskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Availability: Get a Quote. FILES (0) Share this page: Ruskin's Automatic Balancing Dampers provide a reliable way to maintain constant airflow volume and occupant comfort in high-rise buildings. Fiberglass Dampers. to. The webpage also includes diagrams, dimensions, and performance data of the dampers, as well as installation and maintenance instructions. Damper shall be Ruskin model PVC12. See “Smoke Damper Multiple Section Detail” spec sheet for details. 025" thick formed aluminum with concealed blade linkage, synthetic bearings and non. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. 248 Kpa) tested per AMCA 500. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Greaves Rd. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec - ommended maximums. With Seals Dampers 40" (1016) and under – 2 pieces of 18 gage steel. 25" w. g. 165°F or 212°F (74°C or 100°C) (specify temperature) fusible volume adjustment options are available. Mounting Angle Fastener Spacingon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. 1. When installed as shown, they provide appropriate protection for air inlet or outlet penetrations in the ceiling membrane of floor/ceiling and roof/ceiling assemblieslabel and is classified as a static damper for use in HVAC systems that shut down during a fire. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. Example: Maximum design total pressure of 8. Fasteners and Multiple Section Assembly When joining multiple damper assemblies or fastening the damperThe S2SS Backdraft damper has a 2" frame. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. The EFL is STANDARD on all fire/smoke dampers ordered with electric actuators. (Consult for electronic version of this “Quick” spec as well as for complete 3-part CSI MasterFormat Specifications)Ruskin model ABD offers HVAC design engineers an automatic balancing damper which provides: • Energy savings to building owner • Constant maintained airflow volume • Good indoor air quality • Anti-microbial agent prohibiting bacteria or mold growth • Easy installation; requires no tool for adjustment. Maximum rating of 4,000 fpm and 8" w. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. Constructed with durable galvanized steel. Excellent weather protection when installed in. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired. Dampers shall be in all respects equivalent to Ruskin model CBD2. Noise Control. Greaves Rd ansas City, O 600 P: 16 761-776 F 16 765-55 E ruskinruskin. The blades are the same thickness throughout the shape, optimizing the R-Value rating. Note: Multiple section dampers are not intended to be structural supports. 5hr Dynamic Fire Dampers » 3hr Dynamic Fire Dampers » 1. Rev. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. Replacement Electronic Heat Sensors and Pneumatic Fuse Links for Combination Fire Smoke Dampers. Dampers shall incorporate a dish-shaped circular blade mounted to internal slide-Ruskin CD450 is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Galvanized Steel V-Groove Blades. The foregoing limited warranty does not apply to (i) consumable products and components (e. Ruskin Literature. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. (2 kPa). Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. Readily connects to round spiral or flexible ductwork. Enter the Pressure Drop Chart at the determined area factor. Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. Get free shipping on orders over $999!%PDF-1. e. Model CFM Static Pressure Throw In Feet Neck Velocity Jet Velocity Noise Level. H. Ruskin ® 00 Dr. The blades are the same thickness throughout the shape, optimizing the R-Value rating. It features: UL555S Class I leakage class. A. GRANDVIEW, Mo. Frame shall be 16 ga. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). g. The Model IBDT is a thinline fire damper that can be installed vertically in walls and partitions or horizontally in masonry floors with fire resistance ratings of less than 3 hours. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/Steel Stud Wall: #10 screws. Ruskin model SD50 offers HVAC design engineers an ultra-low leak high performance Leakage Class I smoke damper which provides: • Barrier to stop smoke • Lowest pressure drop for energy savings • Optional fail open operation for smoke exhaust applications • Highest dynamic closure rating of 4,000fpm & 8” static pressure. Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Multiple section dampers are available in unlimited sizes. This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Ruskin UL listed solutions are available. Learn about their history, products, news and experts on their website. Axles shall be square or hexagonal positively locked into the damper blade. 765. The "H" dimension represents the required height to encompassRuskin model ARD25 is an automatic round control damper used for clean air circulation in heating, cooling, and ventilation systems. upstream of the damper. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. So turn “on” to energy savings while your building is“off” and let Ruskin start saving you money today. 5 21w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. upstream of the damper. Ruskin backdraft damper model CBDR82 is designed to open under flow and to prevent back-flow in industrial HVAC or process control systems. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. It features a galvanized steel frame, single skin blades, and a variety of actuator options. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. Kansas City, MO 64030 (816) 761 -7476 FAX (816) 765 -8955 L = Diameter + 2 inches (51) "D" Diameter 3. rectangular, airfoil, class IA leakage, heavy duty, 6000 FPM, 13" w. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. The CD60CE is designed for coastal regions and other corrosive environments such as salt-water regions. MINIMUM SIZE Vertical Installation – 4"w x 4"h (102 x 102). (1 kPa). BIM allows for intelligent, 3D and parametric object-based design and provides full bi-directional associativity. back pressure depending on damper size. Ruskin Literature. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for steel joist assemblies (L524). The Ruskin Company’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. 3. Ruskin Literature. Each has added features that enable them to meet all high temperature, high pressure airflow. LEADS; TDP05K Placement Tool; Windload Calculator; Resources. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. Dampers shall be in all respects equivalent to Ruskin model CBD6. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. The FSDR60 is the ideal choice when round duct is used on a project. Welcome to Ruskin Rooftop Systems 972. The ELBD375I Automatic Intake Dual Combination aluminum louver combines a drainable blade louver and an intake backdraft damper in a nominal 9" frame depth. Louver and Architectural Solutions. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Providing accurate control or isolation of. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. G. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. The CD80AF2 Industrial Control damper has an 8" frame. Following system stabilization, normal counter-balance operation will continue. Round Control Dampers. 3 sq. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. CDRS82 ROUND CONTROL DAMPER Spec CDRS82-102/Replaces CDRS82-193 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Dampers shall be in all respects equivalent to Ruskin model IL35. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. Caution: Volume Adjust hangs below a rectangular damper 1 1/8”® Furnish and install at locations shown on plans or in accordance with schedules, bubble tight isolation dampers meeting the following specifications. A 1" (25) diameter jackshaft is normally used. Single Blades. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. Pottorff is a leading manufacturer of AMCA- and UL-certified HVAC louvers and dampers for commercial applications. — Ruskin ® announces three new emergency generator inlet dampers (GenSet) designed to quickly open to relieve combustion air. six plant locations, Ruskin is meeting the needs of contractors and engineers around the globe. 0 psi. @ 1" w. Select the damper size. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. Greaves Rd. When you need to "dial in" branch air flow, Ruskin Model VFBD35 Value Flo "IRIS" Balancing Damper is well suited for ease of installation and labor savings. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade turnsA. Damper shall be Ruskin model CDRS82. All calculations are with external mounted actuators and accessories. For some applications, it is essential that thermal conductivity be kept at a minimum. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. C. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. g. Note: Multiple section dampers are not intended to. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy. We are the leading manufacturer of air and sound. The CFD7T-SR is a UL Classified Ceiling Fire Damper listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548, P572, and H502. It features: Accurate airflow and isolation at extreme elevated temperatures. Ruskin fire dampers may be installed using Ruskin PFMA. 3 m/s) and 8” w. The Ruskin Wireless Inspector™ includes the RFDI (Radio Frequency Damper Interface) located at each damper withCeiling Fire Dampers UL Classified Radiation Dampers for Wood Truss Construction The CFD7T is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586,. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Dampers may tolerate higher pressures and velocities than those listed here. b. We offer a wide variety of products to mee. and greater Carbon steel construction Butterfly bladeThe CFD7T-ST-BT is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. Page 1 INSTALLATION SUPPLEMENTS Horizontal Installation – 90"w x 91"h (2286 x 2311) or 114"w x 38"h. It features: Maximum velocity of 4,000 fpm. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Damper shall be equivalent to Ruskin model ARD25. These dampers are commonly used for vapor cloud and dust cloud explosions found in petroleum, chemical, defense, government, dust collector,. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. 00. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. Ruskin has a comprehensive line of air measuring, IAQ (Indoor Air Quality), and control solutions. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. com. • Damper Styles A, BC, WC, WR and WO • 4000 FPM Max. Grandview, MO 64030 View our location on Google Maps Phone: 816. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. The TS150 must be installed at the factory and cannot be added in the field. Greaves Rd. ft and up to . Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Mounting angles must overlap the partition a minimum of 1" (25). Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired position when fire or smoke (if smoke detector is present) interrupts operational power The EFL or PFL heat-actuated release devices permit controlled. 2. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Unlike conventional mounting angles that cannot be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: One piece angles (fastened together in the corners). Maximum 8" static pressure. The CD60GS is designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment orsurrounding space. Dampers shall be in all respects equivalent to Ruskin Model CD40. Damper Width “A” Dimension in inches (mm)Round Control Damper Class 1A Leakage The CDRS25 “true round” control damper is designed for low to medium pressure and. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and. g. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. Link Bar 5. 2 and can be equipped with factory-mounted actuators. 3. For the name and address of your Ruskin Representative, call (816) 761-7476, or visit our web site at Ruskin can engineer and install pneumatic, electric or manual type actuation to best meet your specifications. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. back pressure depending on damper size. 1/4” cfm at 4” w. 7 %âãÏÓ 69 0 obj > endobj xref 69 77 0000000016 00000 n 0000002434 00000 n 0000002561 00000 n 0000004375 00000 n 0000004685 00000 n 0000005201 00000 n 0000005701 00000 n 0000006313 00000 n 0000006746 00000 n 0000007307 00000 n 0000007930 00000 n 0000007966 00000 n 0000008506 00000 n 0000008619 00000 n. dampers are for use in dynamic (fans on) or static (fans off) sys-tems. Ruskin Literature. Stainless Steel V-Groove Blades. The CDO25 is an oval control damper that features: Volume control. Windstops all around. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. It features: Vertical blades. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. NOTE: Dampers may tolerate higher pressures and velocities than those listed here. Aluminum Airfoil Blades. We always proudly labeled our literature with the AMCA Certified Ratings Logo and now we will be labeling on dampers as well. The Damper part prices in this catalog do include freight within the contiguous 48 states. 2. Unlike other ceiling. (0. 25" w. 2. Dampers may tolerate higher pressures and velocities than those listed here. specification but their recommendedThe ZMD60 Zone Mixing Damper is suitable for multiple zone applications where high performance is required. 5, CFD4 and CFD(R)5 are UL labeled ceiling radiation dampers. ft. Greaves Rd. Dampers above 40" (1016) – 10 gage with retainer ring. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Ruskin (Thailand) Co. Aluminum construction. CD60 | Galv. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. g. Each has added features that enable them to meet all high temperature, high pressure. Stainless Steel Construction See model (D)IBD2SS. Ruskin May 2020 Page 1 Models CFD(R)2, CFD(R)3, CFD(R)3. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. It features: Low leakage. Product offerings include Air Control & Distribution products,. Maximum rating of 4,000 fpm and 4" w. Designed to protect life and property, Ruskin® manufactures a complete line of UL classified dampers. Determine area factor for damper by entering the Area Factor Table through duct width and height. g. Elevated temperature categories begin at 250°F and increase in increments of 100°F. , which meets the International Energy Conservation Code (IECC) requirements. TION 1. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Higher velocities are not recommended for outside air openings, due to water penetration concerns. See “Combination Fire Smoke Damper Multiple Section Detail” specPerfect for a Wide Variety of Applications. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below on dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Inspiring the industry with thought provoking, revolutionary ideas, Ruskin airfoil blade dampers comprise the only damper design incorporating a single piece roll-formed frame and blade. g. 3. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. When used in fan discharge applications, damper should be the damper frame. CDR25 and CDO25 dampers are round and oval volume control dampers. Horizontal mount dampers may be installed with the jackshaft above or below the floor. The CFD8 is UL555C Classified Ceiling Fire (Radiation) Damper (CABS. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. The Manufacturers we represent are industry leaders such as Loren Cook (fans), Ruskin (dampers, louvers) and Krueger (air distribution products). yeoching. Sun Control Sunshades. 75" w. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. 5. Greaves Road Grandview MO 64030 Phone: 816-761-7476 ruskin@ruskin. Leakage information based on pressure differential of 1" w. Our dampers are ideal for outdoor air applications that require low leakage or heavy duty industrial needs to prevent hot or cold outside air penetrating your building. 4) steel. Email. Ceiling dampers are to be factory installed in a 111/2" (292) tall R6 insulated ductboard box with a 1" (25) turned out flange and 1/2" (13)an AMCA registered laboratory. FSD36 126"x 96"or 72"x 122" 4"w. Maximum Damper Width (A Dimension) Maximum Damper Width (A Dimension) AREA FACTOR TABLE EXAMPLE: 1. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. per sq. What is an EFL device? The Ruskin electronic "resettable" fuse line (EFL) is a UL Classified heat response device for use in conjunction with Ruskin fire/smoke dampers. The new DC "data center" models are high-performing airfoil blade type, and offer the lowest AMCA Class 1A leakage rating for energy savings. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Ruskin Green Products. UL approval for dual directional airflow. The Diffuser Radiation Shield, which allows any manufacturer's lay-in style steel ceiling diffuser (subject to gage and dimension limitations) to be installed in UL Classified F/C or R/C assembly with Fire. Corrosion. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. II-FSD36-0121/ Replaces II-FSD36-514 ©Ruskin January 2021 ® APPLICATION The FSD35, FSD36 and FSD37 are combination fire and smoke dampers designed to restrict the passage of flame and resist the passage of smoke. Maximum velocity of 4,000 fpm. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. 8) galvanized steel struc-Products. Easy installation. Marketing Literature; Case Studies;. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. The SDRS25 is a UL555S Classified round smoke damper. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade Louver and Architectural. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Greaves Rd. 25" w. 4 inches w. g. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. lbs. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476 Document Title O & M for Commercial Control Dampers Limited Warranty Document LINKS TO IMPORTANT. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. 2 m/s) and 4” w. High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. A. Standard features vary by model to make application selection straightforward. g. See “Smoke Damper Multiple Section Detail” spec sheet for details. Face and by-pass arrangement. g. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec-ommended maximums. Expansion Clearance – The opening in the wall or floor must be a minimum of 1/8" per foot (3 per 305) larger than the overall damper/sleeve assembly. Mounting Angle FastenersCurtain Type Static Fire Dampers 3 Hour Ul555 Rated For Use In Static Systems Ruskin Model IBD23 is a 3 hour UL classified static (fans off) curtain style fire damper for use in HVAC systems that shut down during a fire event. Do not weld or fasten angles together at cor-ners of dampers. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. • Fire smoke dampers larger than single section may require multiple actuators. The damper is rated for5 82w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. 3 m/s) and 8” w. angles together at corners of dampers. and a maximum of 3 CFM sq. static pressure. Testing has proved that the CD40x2 insulated more efficiently than conventionally insulated blades. It features: Extremely low leakage. Dynamic fire dampers shall be Ruskin multiple model DFD35. of damper with minimum of 20 in. Stops the leakage of smoke in static and dynamic smoke systems. /Class III, V-Groove Blade,. It features: AMCA Class 1A leakage for energy savings R value – 2. Most F/Cs andSMOKE & COMBINATION FIRE SMOKE DAMPER ACTUATORS. • For proper operation, damper must be installed square and free from racking. SP100: Dampers shall be equipped with factory installed damper position indication switch package. MAXIMUM SIZE Single section Vertical Installation DIBD2 - 32"w x 36"h (813 x 914). • Ruskin frame-mounted actuator bracket to simplify field installation of most actuators (specify actuator and action, i. Ceiling Fire Dampers UL Classified Radiation Dampers Underwriters Laboratories has classified hundreds of specific Floor/Ceiling (F/Cs) and Roof/ Ceiling (R/Cs) and established Fire Resistance Ratings for each design ranging from 1/2 to 5 hours. The CD60GS also provides AMCA class 1A leakage rating of 3cfm/ft2 at 1”. Industrial Fiberglass Louvers. at 4" w. The Damper part prices in this catalog do include freight within the contiguous 48 states. ft. 7476 Fax: 816. 765. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. com . Ruskin smoke damper and actuator assemblies qualify. INSTALLATION Install with frame square without twisting or racking. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. of damper with minimum of 20 in.